E44-1082 · Other · Sight Glass · ★★
Fouled, hazy, unreadable.
[Mechanism] Fouling on the inner wall or a turbid medium cut light transmission, making the liquid level unobservable.
[Calculation] The Φ100 sight glass had a 0.3mm fouling layer; light transmission dropped 60%, and the level was misjudged.
[Design Omission] No flushing, no good-transmission material, and no inspection.
1) Provide a flushing device (periodically flush the glass face); fouling blocks the view, and flushing clears it;
2) Choose a good-transmission material (tempered glass + mica); poor material blocks the view, and good material makes it clear;
3) Add a wiper (scrape the fouling); sticky fouling blocks the view, and wiping cleans it;
4) Control the viewing position (adequate lighting); darkness blocks the view, and good lighting makes it readable;
5) Run a clarity check (level visible within ±10mm); obstruction was un-inspected, and measured clarity confirms it;
6) Fit a level reference (external level gauge); fouling first shows as an obscured view, and early warning catches it;
7) Set a fixed wiping interval in operation (every shift); long intervals obscure, and controlled intervals keep it clear;
8) Record flushing and material choice in the sight-glass specification; the root cause of fouling was no flushing and poor material, so the specification must gate it.
GB/T 23252-2009 Sight glasses for pressurized equipment