E44-659 · Level Control Failure · Float magnet · ★★
Demagnetized, no flip, signal lost
[Mechanism] Demagnetization stops the flag from flipping.
[Calculation] The demagnetization loses the signal.
[Design Omission] No heat-resistant magnet was selected, no insulation and no checks were provided — so it demagnetized.
1) Switch to a heat-resistant magnet (samarium-cobalt, rated ≥250℃): because the original ordinary magnet demagnetized at a medium temperature >150℃ (flux density dropping from 0.06T to 0.02T) and its weakened force stopped the flag flipping, the heat-resistant magnet holds so it flips again;
2) Add a heat-insulating sleeve to cool it (a heat-blocking conductive sleeve): because heat demagnetizes it and the sleeve shields it, the magnet's life is extended;
3) Hold the temperature ≤ the magnet limit (operating temperature ≤ 60% of the magnet's Curie point): because high temperature demagnetizes it and temperature control protects it, demagnetization is prevented;
4) Verify the field strength (measure the flux density, replace below 0.04T): because a weak field stops the flip and checking warns, replacement is timely;
5) Select a stable magnetic circuit (encapsulated against moisture): because an unstable circuit demagnetizes and a stable one holds, the magnetism is steady;
6) Check the magnet condition (measure the field strength annually): because gradual demagnetization loses the signal and checking gives early warning, it is replaced in advance;
7) Set a service-life replacement (≤3 years): because age demagnetizes it and a fixed life forces replacement, signal loss is prevented;
8) Write the heat resistance and magnetic insulation into the specification: the original failure to select a proper magnet was the root cause of the demagnetization, so the spec locks it in and specification governs it.
HG/T 21550-1993 Level gauges