E44-1013 · Insufficient Vessel Strength and Wall Thickness · Vessel · ★★★
Local stress over limit, cracking, leakage
[Mechanism] Nozzles, supports, and attachments penetrating the shell create local stress concentration beyond the GB/T 150 allowable limit.
[Calculation] The local stress of 205MPa exceeds [σ]=185MPa (by 11%); the stress-concentration factor is 2.0, and no reinforcement was provided.
[Design Omission] No reinforcement, no local-stress check, and no smooth transition.
1) Add reinforcement (integral reinforcing forging or reinforcing pad); skipping reinforcement concentrates stress, reinforcement lowers it, reducing stress;
2) Check local stress (local σ≤[σ], including concentration); 205>185 causes cracking, checking reveals it, quantifying the margin;
3) Switch to a heavier shell (δ=12mm, was 8mm); a thin wall is weak, a thick wall raises strength, increasing capacity;
4) Make the transition smooth (R≥3δ); a sharp corner cracks, a smooth transition relieves it, lowering stress;
5) Perform local magnetic-particle inspection (no cracks); cracks first show as lines, and early screening removes them;
6) Perform a hydrostatic test (1.25× design pressure); exceeding the allowable limit cracks it, measured data confirms stability;
7) Control the auxiliary loads (shared by supports and hangers); auxiliary loads add stress, sharing them lowers the load;
8) Record reinforcement and stress checks in the calculation dossier; the root cause of over-limit local stress was skipped reinforcement and unchecked stress, so the calculation must gate it.
GB/T 150.1-2011 Pressure vessels