MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Fluid Systems Error Case › Inadequate Seismic Resistance of a Pressure Vessel

Inadequate Seismic Resistance of a Pressure Vessel

E44-1012 · Insufficient Vessel Strength and Wall Thickness · Vessel · ★★★

Problem Description

Inadequate seismic resistance, cracking, overturning

Root Cause

[Mechanism] No seismic design was done; the anchorage and supports cannot resist the horizontal seismic force, so the vessel overturns or ruptures.
[Calculation] Seismic fortification intensity 8, a=0.2g; the uplift force is 150kN; the original 4×M20 anchor bolts carry only 90kN — 60kN short; the overturning safety factor K=0.75<1.5.
[Design Omission] No seismic fortification, no anchorage check, and no diagonal bracing.

Corrective Solution

1) Add anchorage (8×M24 replacing 4×M20, carrying 200kN); uplift of 150>90 causes overturning, added anchors stabilize it, resisting overturning;
2) Check the anchorage uplift capacity (carry ≥1.5× uplift = 225kN); inadequate capacity overturns it, a checked anchorage protects it, making anchorage compliant;
3) Add diagonal bracing / tie rods (bidirectional H150); seismic shaking overturns it, braces tie it down, resisting shear;
4) Raise the foundation capacity (enlarged C30); a weak foundation cracks or overturns, raised capacity stabilizes the seat;
5) Use flexible nozzle connections (bellows compensation); rigid connections crack, flexible ones relieve, lowering stress;
6) Perform a seismic check (response-spectrum method, K≥1.5); skipping the calculation overturns it, computing verifies it, and data sets the stability;
7) Keep liquid fill ≤80% (reduce seismic mass); a full tank sloshes, controlled fill stabilizes it, preventing motion in service;
8) Record bracing and anchorage checks in the assembly card; the root cause of inadequate seismic resistance was skipped seismic design and weak anchorage, so assembly must gate it.

Checklist

Reference

GB/T 150.1-2011 Pressure vessels

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL