E44-132 · Uneven Flow Distribution · Synchronous flow divider valve · ★★
Flow-division accuracy ±8% (required ±3%), the two cylinders lose synchronization and stick
[Accuracy] The valve accuracy is insufficient.
[Calculation] A ΔQ of ±8% accumulates into a stroke difference.
[Design Omission] No high-accuracy flow divider valve was selected, so the cylinders desynchronize.
1) Select a high-accuracy synchronous flow divider valve (accuracy within ±3%), because accuracy determines synchronization, thereby reducing the error;
2) Provide a closed-loop displacement-synchronization feedback for the two cylinders, because closed loop is more accurate than open loop, thereby synchronizing;
3) Make the piping equal in length and diameter to reduce deviation, because similar impedance evens the flow, thereby synchronizing;
4) Calibrate and inspect the flow divider valve at fixed intervals, because drift causes a difference, thereby recalibrating;
5) Provide a synchronization out-of-tolerance alarm, because exceeding the tolerance triggers an alarm, thereby giving early warning;
6) Design for balanced load to prevent off-center loading, because an even load keeps synchronism, thereby steadying it;
7) Measure the two-cylinder synchronization at commissioning (≤±3mm), because the design requires measurement, thereby confirming delivery;
8) Build the flow-division accuracy into the synchronization design, because insufficient accuracy was the main cause, thereby freezing it to prevent recurrence.
GB/T 3766-2015 Hydraulic fluid power - General technical conditions