Knowledge Base › Fluid Systems Error Case › Uneven Branch Resistance Causing Distribution Imbalance

Uneven Branch Resistance Causing Distribution Imbalance

E44-180 · Uneven Flow Distribution · Four-branch distribution system · ★★

Problem Description

Four branches of the same diameter but different lengths, flow ratio 1.4:1.2:0.9:0.5 out of balance, the far end starved

Root Cause

[Resistance Mismatch] Different branch lengths make the resistances unequal.
[Detuning] The near branches fight for flow and the far end is starved.
[Design Omission] No balancing valves and no adjustment were provided, so the distribution is out of balance.

Corrective Solution

1) Fit a balancing valve on each branch to even the resistance and the flow, because different lengths make the resistances unequal and the flow ratio 1.4:0.5 is out of balance, thereby balancing it;
2) Design the branches for equal resistance with equal length and diameter, because different lengths cause a resistance difference, thereby equalizing the resistance;
3) Fit a flowmeter to monitor each branch, because a deviation becomes visible, thereby monitoring each branch;
4) Verify the flow of the most unfavorable branch, because the far end is starved, thereby verifying the far branch;
5) Calibrate the valves to the calculated opening, because the opening affects the resistance, thereby calibrating the opening;
6) Measure the flow balance of each branch at commissioning, because the design requires measurement, thereby confirming delivery;
7) Keep a balancing-commissioning record, because the adjustment must be documented, thereby recording it;
8) Build the balancing into the distribution design, because the missing balancing was the root cause of the imbalance, so the design must include it.

Checklist