E44-131 · Uneven Flow Distribution · Three parallel booster pumps · ★★
Three parallel pumps with a flow ratio 1.3:1.1:0.6, one pump deadheads and overheats
[Flow Imbalance] The characteristic curves differ.
[Calculation] At the same head the flows differ greatly and one pump deadheads.
[Design Omission] The pumps were not of the same type and characteristic, so the flow is unbalanced.
1) Select pumps of the same model and characteristic curve for parallel operation, because similar characteristics even the flow, thereby evening it;
2) Fit a balancing valve at each pump outlet, because adjustability evens the flow, thereby reducing the imbalance;
3) Run the pumps with variable-frequency drives at the same speed, because the same speed means the same operating point, thereby evening them;
4) Monitor the flow of each pump, because a deviation becomes visible, thereby adjusting early;
5) Verify the parallel operating point against deadheading, because a deadheaded pump overheats, thereby avoiding it;
6) Provide cavitation monitoring at the inlet, because it prevents the pump from running dry, thereby steadying it;
7) Measure the flow balance and confirm no deadheading at commissioning, because the design requires measurement, thereby confirming delivery;
8) Build the parallel-pump design into the pump house, because mismatched types were the main cause, thereby freezing it to prevent recurrence.
GB/T 20801.3-2020 Pressure piping code - Industrial piping - Design