Parallel Pumps Fighting for Flow

E44-737 · Uneven Flow Distribution · Parallel pumps · ★★

Problem Description

Pumps fighting for flow, deviation, characteristic difference

Root Cause

[Mechanism] Parallel pumps fight for flow and the flow deviates.
[Calculation] A difference in characteristic makes the pumps fight for flow.
[Design Omission] No matching of characteristics, no adjustment, and no inspection were provided, so the characteristics differ.

Corrective Solution

1) Match the pumps to the same characteristic curve (same model and impeller, coincident Q-H curves), because the original characteristic difference made the larger pump rob the smaller one in parallel and the flow deviate by >25%, thereby matching the characteristics and splitting the flow evenly;
2) Steady the header pressure (header diameter ≥2 times the branch, pressure fluctuation ≤2%), because a pressure difference makes the pumps fight and steadying evens them, thereby steadying the pressure;
3) Verify the flow of each pump (fit a meter on each pump, alarm above 5%), because a difference causes deviation and verification reveals it, thereby verifying the flow;
4) Add balancing valves for adjustment (on the header, adjust for evenness), because fighting for flow causes deviation and adjustment splits the flow, thereby adjusting evenly;
5) Limit each pump (each pump ≤90% of rated), because fighting for flow causes deviation and limiting eases it, thereby limiting the upper end;
6) Monitor the fighting condition (current of each pump, alarm above 10%), because gradual fighting is invisible and monitoring catches it, thereby giving early warning;
7) Run a parallel test (same head, accept when even), because the lack of testing caused the fighting and testing verifies it, thereby testing the parallel operation;
8) Write the characteristic matching and pressure steadying into the specification (parallel characteristic verification), because the missing matching was the root cause and freezing it into the specification enforces control.