E44-899 · Siphon and Backflow · Siphon Pipe · ★★
Loss of suction, flow break, stoppage
[Mechanism] When the siphon starts the pipe is not completely filled, and air entering at the high point during operation makes the absolute pressure at the top of the liquid column drop toward the vapor pressure, breaking the liquid column.
[Calculation] The maximum siphon vacuum is h_v=H_top+H_loss; here H_top=11.5 m and H_loss=0.8 m give h_v=12.3 m >10.3 m (atmospheric water column), the top pressure=10.3−12.3=−2.0 m as a negative pressure over the limit, breaking the liquid column; the safety limit h_v≤9.5 m requires H_top≤8.7 m.
[Design Omission] No h_v≤9.5 m check, no high-point venting and no foot-valve priming, so the flow breaks on the very first start.
1) Verify the siphon height so that h_v≤9.5 m (originally H_top=11.5 m, over the 10.3 m limit), because the top absolute pressure=10.3−h_v and h_v>10.3 m means a negative pressure that breaks the liquid column, thereby lowering H_top to ≤8.7 m so the top pressure is ≥0.8 m water column and the siphon establishes steadily;
2) Provide a foot valve plus priming on start (fill the pipe completely and expel the air before starting), because residual air collects at the high point and is carried to the top during operation and breaks the vacuum, thereby eliminating the air source by filling the pipe before start so suction establishes in one attempt;
3) Install an automatic vent valve at the high point (auto-venting at vacuum >8.5 m), because dissolved gas comes out of solution and slowly accumulates at the high point during operation, gradually dropping the vacuum, thereby venting in time to maintain the vacuum;
4) Reduce the local losses (elbows from 8 to 3, R≥5D), because Σξ drops from 4.2 to 1.6, lowering H_loss from 0.8 to 0.3 m and h_v by 0.5 m, thereby reducing the height requirement to restore suction;
5) Install a vacuum gauge plus alarm at the high point (alarm on vacuum <7.0 m), because the vacuum falls gradually before the stoppage, allowing early intervention, thereby monitoring the vacuum to prevent a sudden stoppage;
6) Raise the velocity to 1.2–1.5 m/s (originally 0.8 m/s), because at low velocity air readily separates, floats up and accumulates while higher velocity carries it out with the flow, thereby suppressing accumulation;
7) Run a monthly siphon-hold test (check the pipe stays full and runs continuously without breaking), because seals age and leak slowly, the vacuum gradually being lost, thereby quantifying the leak rate to guide maintenance;
8) Write the h_v≤9.5 m check and foot-valve priming into the siphon design specification, because the root cause of lost suction is no height check and no priming on start, thereby the specification controls it to eliminate recurrence.
GB/T 20801.3-2020 Design code for industrial metallic piping