E44-535 · Heat Exchanger Fouling and Insufficient Heat Exchange · Plate-Type Brewing Wort Heat Exchanger · ★★
Wort coking on surfaces, reduced K, insufficient sterilization, off-flavor
[Mechanism] High-temperature wort cokes onto the surface.
[Calculation] Rf=0.4 lowers K by 35%, leaving sterilization temperature insufficient and causing off-flavor.
[Design Omission] Wall temperature was not controlled and no CIP was done, so coking occurred.
1) Control wall temperature (≤ wort coking threshold, outlet sterilization temperature meets spec) and run CIP (alkali wash every batch); because high-temperature wort cokes on surfaces, Rf=0.4 lowers K by 35%, and insufficient sterilization temperature causes off-flavor, temperature control suppresses coking while CIP restores K and preserves sterilization;
2) Preheat the feed (plate inlet temperature ≥ design lower limit); because cold feed entering plates causes local over-cooling and intensified deposition, preheating equalizes temperature and suppresses deposition;
3) Add a sterilization-temperature alarm (alarm when sterilization temperature falls below the process limit); because coking lowers K first as insufficient sterilization temperature and flavor risk, monitoring gives early warning;
4) Raise flow velocity (≥1.5 m/s) to prevent stagnation; because long residence in low-velocity zones and wall temperature rise promote coking, higher velocity reduces residence time and suppresses coking;
5) Switch to non-stick surfaces (mirror polish / Teflon coating); because coke readily adheres to rough surfaces and non-stick surfaces reduce adhesion, changing the material suppresses coking;
6) Schedule disassembly washing (plate removal and high-pressure flush every two weeks); because the coke layer adheres strongly once cured, periodic disassembly washing restores flow area;
7) Control concentration (wort concentration ≤ process upper limit); because concentrated wort is highly viscous and cokes on walls, concentration control suppresses coking;
8) Write temperature control and CIP into the wort heat exchange procedure; because the original design omitted wall-temperature control and CIP, the root cause of coking, the procedure closes the loop.
GB/T 151-2014 Heat exchangers