Knowledge Base › Fluid Systems Error Case › Textile Dye Heat Exchanger Fiber Blockage

Textile Dye Heat Exchanger Fiber Blockage

E44-536 · Heat Exchanger Fouling and Insufficient Heat Exchange · Tubular Textile Dye Heat Exchanger · ★★

Problem Description

Fibers adhere in dye liquor, blockage, reduced flow, uneven temperature

Root Cause

[Mechanism] Fiber clumps jam in the tubes.
[Calculation] Fiber length > tube diameter, 35% hole blockage, velocity v rises, Δp=0.15, uneven temperature.
[Design Omission] No filtration and no flushing, so fiber blockage occurred.

Corrective Solution

1) Pre-filter the dye liquor to remove fibers (mesh ≤0.5mm); because fiber length > tube diameter, 35% hole blockage, rising v, Δp=0.15 and uneven temperature, pre-filtering removes fibers, restores passages and keeps temperature uniform;
2) Schedule backwashing (reverse wash each shift, intensified flush at Δp>0.12MPa); because fiber buildup reduces flow area and differential pressure rises before full blockage, periodic backwashing removes fibers;
3) Add a differential-pressure alarm (alarm at Δp>0.15MPa); because fiber blockage raises differential pressure before flow visibly drops, it gives early warning of fouling;
4) Raise flow velocity (≥1.2m/s) to prevent settling; because fibers settle and adhere in low-velocity zones and jam tighter over time, higher velocity reduces residence time and suppresses settling;
5) Widen tube diameter (≥ design lower limit +2mm); because narrow tubes trap fibers and cannot be cleaned thoroughly, wider tubes ease flushing;
6) Inspect fiber buildup on schedule (bi-monthly borescope / visual); because fibers thicken and worsen Δp and temperature unevenness, quantifying it guides the backwash interval;
7) Add loop filtration (filter the dye return line); because more fibers mean re-deposition and return-line filtration cuts the load, loop filtration suppresses blockage;
8) Write pre-filtration and backwashing into the textile heat exchange procedure; because the original design omitted filtration and flushing, the root cause of fiber blockage, the procedure closes the loop.

Checklist

Reference

GB/T 151-2014 Heat exchangers