Flange Parallelism Out of Tolerance Causes Leakage

E44-564 · Seal Leakage · Flange Pairing · ★★

Problem Symptom

Leakage, parallelism 1.5mm against 0.5mm, eccentric gasket loading

Root Cause

[Mechanism] Lack of parallelism makes the gasket load eccentric.
[Calculation] A 1.5mm offset against 0.5mm drives the local gasket pressure to 0 and it leaks.
[Design Omission] The joint was never aligned, the parallelism was never checked, and no accommodation was added - the joint was eccentric.

Correct Solution

1) Adjust the flange parallelism to <=0.5mm (gasket gauges and feelers); the original 1.5mm against 0.5mm drove the local gasket pressure to 0 so it leaked, and aligning it equalises the pressure and stops the leak;
2) Fit alignment dowels (assembly guide pins); an offset distorts the joint and spoils the parallelism, so the dowels prevent the offset;
3) Check the parallelism (at every weld joint); the joint drifts gradually and then leaks, so the parallelism is checked;
4) Select a thicker gasket to accommodate the offset (a 3mm spiral-wound gasket accepts 1mm of offset); a thin gasket cannot conform to the offset, so thickening it adds tolerance;
5) Fix the supports and hangers to prevent movement (add supports); movement causes the offset and changes the parallelism, so fixing the supports prevents it;
6) Tack symmetrically before welding to prevent distortion (alternating tacks); weld shrinkage distortion causes the offset, so tacking prevents it;
7) Set a routine parallelism check (at each maintenance shutdown); the offset develops gradually and then leaks, so the parallelism is checked;
8) Write the alignment and the parallelism check into the assembly card; the original failure to align was the root cause of the offset, so the assembly card closes the loop.

Checklist

References

GB/T 50235-2010 Code for Construction of Industrial Metallic Piping

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL