Scratched Flange Sealing Face Causes Leakage

E44-563 · Seal Leakage · Flange Face Ra6.3 · ★★

Problem Symptom

Leakage, scratch 0.1mm deep against 0.05mm allowed, linear leakage

Root Cause

[Mechanism] A scratched face breaks the line seal.
[Calculation] A scratch depth of 0.1mm against the 0.05mm allowed breaks the line seal band and it leaks.
[Design Omission] The face was not protected, Ra was never inspected, and the face was not reground - the damage was left in place.

Correct Solution

1) Regrind the face to Ra1.6 (grinding plus lapping); the original Ra6.3 and the 0.1mm deep scratch against the 0.05mm allowed broke the line seal band so the medium leaked along the groove, and reducing the roughness restores the band and stops the leak;
2) Fit a face protection cover (cover the face during installation); the bare face is scratched by weld spatter and tools, so protection prevents renewed damage;
3) Inspect Ra<=3.2 (template colour comparison before assembly); a rough face does not seat the gasket tightly and leaks, so the Ra check is the gate;
4) Replace the damaged flange (scratch deeper than 0.1mm or through the material); a deep scratch cannot be ground out and the line seal band is permanently broken, so the part is changed;
5) Clean the face and remove debris before assembly (white cloth and solvent); debris trapped in the face causes a local leak, so cleaning the face prevents it;
6) Select a soft gasket to compensate for the damage (flexible graphite fills 0.1mm micro-damage); a hard gasket cannot conform to the damage but a soft one compensates, so the soft gasket is the emergency remedy;
7) Set a routine face damage inspection (at every dismantling); damage progresses gradually and then leaks, so the face is inspected;
8) Write the face protection and the Ra inspection into the assembly card; the original absence of face protection and Ra inspection was the root cause of the damage, so the assembly card closes the loop.

Checklist

References

GB/T 9124-2019 Steel Pipe Flanges

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL