E44-807 · Piping Supports and Thermal Expansion · Pipe Clamp · ★★
Pipe clamp loose, pipe rubbed, wall thinned
[Mechanism] The pipe clamp is not tight, so the pipe and the clamp rub.
[Calculation] Looseness makes the pipe vibrate and rub, thinning the wall >0.3mm per year.
[Design Omission] Neither tightening nor anti-loosening was provided — so the clamp must be tightened.
1) Tighten the pipe clamp against loosening (torque to spec, double nuts): because the original looseness made the pipe vibrate and rub and thinned the wall >0.3mm per year, tightening the clamp prevents the rub;
2) Add a spring washer against loosening (spring washer + threadlocker): because vibration loosens and prevention secures it, loosening is prevented;
3) Add a pipe-protection pad (a non-metallic liner in the clamp): because hardness rubs and a pad protects, the pad is added;
4) Inspect the looseness (check the torque periodically, alarm on looseness): because progressive looseness worsens the rub and early awareness helps, looseness is inspected;
5) Weld stops against slipping (stop blocks prevent axial slipping): because slipping rubs and a stop prevents it, stops are provided;
6) Perform a hold test (check the clamp tightness under vibration): because the original lack of testing left the rub undiscovered, the test reveals the tightness, so hold is tested;
7) Control the vibration source (damp the vibration and reduce the amplitude): because vibration loosens and control relieves it, vibration is controlled;
8) Write the clamp tightening and anti-loosening into the maintenance card: the original lack of tightening was the root cause of the looseness, so maintenance controls the work and the clamp does not loosen.
GB/T 17116.1-2018 Pipe supports and hangers