Problem Description

Wrong hanger selection, pipe sag >40mm, load lost

Root Cause

[Mechanism] Wrong load selection for the spring hanger loses the load and the pipe sags.
[Calculation] The wrong selection deviates the working load >20% and sags the pipe >40mm.
[Design Omission] The load was neither calculated nor selected — so it must be calculated.

Corrective Solution

1) Recalculate the load and replace the hanger (select the model from pipe weight + medium ×1.2): because the original wrong selection deviated the working load >20% and sagged the pipe >40mm, the load is recalculated and the hanger replaced;
2) Check the load match (weigh it and compare with the spring characteristic table): because a mismatch sags and the check makes it accurate, the load is checked;
3) Select a suitable hanger travel (travel ≥ thermal displacement + margin): because too little travel restricts and a suitable selection is adequate, the travel is selected;
4) Adjust the pre-compression (set it to the scale load in the cold state): because looseness sags and adjusting carries the load, the pre-compression is adjusted;
5) Inspect the selection (read the pointer / measure the displacement, alarm on deviation): because progressive error enlarges the sag and early awareness helps, the selection is inspected;
6) Perform a load test (load it and record the displacement curve): because the original lack of testing left the sag undiscovered, the test identifies the load points, so the load is tested;
7) Keep the pipe weight stable (distribute evenly between supports to cut the per-hanger load): because a changing duty sags and even distribution stabilizes it, the weight is stabilized;
8) Write the load calculation and hanger replacement into the specification: the original design omission was the root cause of the error, so the specification controls the work and the hanger is correct.