E44-348 · Excessive Piping Resistance and Pressure Drop · Metering disturbed by short straight run after a bend · ★★
A short straight run after a bend leaves secondary flow unresolved, distorts the velocity profile, raises equivalent resistance 10%, and biases metering
[Mechanism] Unresolved vortices after a bend distort the velocity profile and raise equivalent resistance.
[Calculation] The 10% rise in equivalent resistance biases metering.
[Design Omission] No straight run left and no flow straightener - secondary flow resistance remained.
1) Leave a ≥10D straight run or fit a straightener after bends, since the short run left secondary flow, raised resistance 10% and biased metering, stabilizing flow and the profile;
2) Fit a straightening grid to correct the velocity profile, since distortion raises resistance, straightening the flow;
3) Check the added secondary-flow loss, since vortices lose energy, accounting for it;
4) Put a long straight run ahead of the metering point, since metering needs steady flow, using a long straight run;
5) Optimize the post-bend layout, since bends create vortices, optimizing the arrangement;
6) Avoid short straight runs at the pump outlet too, since the same fault applies, avoiding short runs;
7) Periodically measure and compare the profile, since distortion creeps, profiling it;
8) Write the straight-run requirement into the layout, since the missing run was the root cause, closing the loop at layout.
GB/T 20801.3-2020 Design code for industrial metallic piping