E44-049 · Other · Dosing Metering Pump · ★★
Diaphragm deformation drove the actual flow 12% off (allowable ±1%), the dosing concentration overshot, and the product was out of spec.
[Stroke Deviation] Diaphragm creep changes the effective stroke; flow Q=n·Vs·η_v drops.
[Concentration] Dosing amount off-spec pushes the reaction concentration out of range.
[Design Omission] No calibration and no medium-temperature control; the deviation made the product out of spec.
1) Calibrate pump flow at the factory and recheck periodically; diaphragm creep changes the effective stroke and flow drifts 12% (allowable ±1%), so calibration corrects the offset;
2) Choose a creep-resistant diaphragm material; creep-resistant material deforms little and holds flow steady, so select the material;
3) Control medium temperature to prevent deformation; temperature drives diaphragm creep and stroke change, so control temperature;
4) Provide both stroke and frequency adjustment; dual adjustment precisely controls flow, so tune both;
5) Add online dosing-concentration feedback; over-range concentration makes the product out of spec, so feed it back;
6) Provide a standby pump for switchover; a standby unit keeps operation continuous, so have a spare;
7) Measure flow deviation on commissioning at ≤±1% (was 12%); a small deviation means accuracy, so verify it;
8) Bring calibration into metering management; the original lack of calibration was the root cause of deviation, so management must include it.
GB/T 7782-2018 Metering pumps