E44-048 · Other · Steam Ejector · ★★
Low working-steam pressure gave insufficient pumping capacity; the vacuum fell 5kPa and condensation was poor.
[Ejector] Low working-steam pressure p lowers the entrainment ratio u; pumping capacity Q∝u.
[Vacuum] Insufficient pumping leaves the system vacuum low.
[Design Omission] Working steam was not pressure-regulated and the entrainment ratio was not calculated; weak suction caused the poor result.
1) Regulate the working-steam pressure to the rated value; low p lowers the entrainment ratio u, pumping Q∝u falls short, and vacuum drops 5kPa, so regulate pressure to hold u;
2) Size the nozzle by the entrainment ratio; the ratio sets the nozzle dimensions, so size the nozzle by the ratio;
3) Replace a worn nozzle promptly; wear changes the throat diameter and lowers u, so replace the nozzle;
4) Match ejector stages to the pumping load; multiple stages raise total pumping capacity, so stage them;
5) Check condenser capacity; poor condensation leaves vacuum low, so verify condensation;
6) Monitor pressure and vacuum; monitoring catches anomalies early, so watch them;
7) Measure vacuum on commissioning against design; meeting the target proves it, so verify it;
8) Bring the entrainment ratio into ejector design; the original failure to calculate it was the root cause of weak suction, so the design must compute it.
GB/T 150.3-2011 Pressure vessels - Design