Valve Installed in the Reverse Direction Causes Leakage

E44-1037 · Valve Selection & Internal Leakage · Valve · ★★

Problem Symptom

Reverse installation, leakage, backflow

Root Cause

[Mechanism] A check valve or globe valve was installed in the wrong direction, so the medium flows backwards or the globe valve cannot close tightly and leaks in reverse.
[Calculation] DN150 check valve installed backwards, with a forward-flow resistance of xi=2.5 (0.5 or less is required), the disc cannot seat in reverse and 30m3/h flowed backwards.
[Design Omission] The flow direction was never checked, no arrow was marked, and no direction inspection was performed.

Correct Solution

1) Reinstall according to the flow direction (the body arrow aligned with the medium); the original reverse installation leaked and correct installation stops the backflow;
2) Mark the flow direction arrow (with conspicuous paint); blind installation causes reversal and marking the flow makes it clear, keeping the direction controllable;
3) Change to a valve that is already correctly installed (confirm the disc seats); reverse installation leaks and correct orientation seats it, sealing the valve;
4) Carry out a flow-direction test (flow forward, blocked in reverse); the leak was never verified and measurement confirms the direction, so the data fixes the orientation;
5) Fit a flow meter downstream of the check valve (monitor a reverse flow of zero); backflow shows up first as reverse flow and early detection gives warning, monitoring the direction;
6) Perform a direction review (label every valve with its tag number); mixed-up valves get reversed and the review confirms it, preventing misinstallation;
7) Keep the upstream pressure above the downstream pressure in operation (to prevent backflow); a reversed pressure difference causes backflow and controlling the difference stops it, preventing backflow in operation;
8) Write the direction verification and flow marking into the assembly card; the root cause of the reverse installation was a missing flow-direction check with no marking, so the assembly card closes the loop.

Checklist

References

GB/T 12224-2015 Steel Valves - General Requirements