E44-143 · Insufficient Vessel Strength and Wall Thickness · Vacuum distillation tank (-0.09MPa) · ★★★
Not checked for external pressure, the shell buckled circumferentially and collapsed, with a local depression 40 mm deep
[External Pressure Instability] External pressure buckles the shell; the critical pressure pcr∝(t/D)².
[Collapse] A thin wall makes pcr<0.09MPa, causing instability and depression.
[Design Omission] Not checked as an external-pressure vessel and no stiffening rings added, so it collapsed.
1) Verify the critical pressure pcr as an external-pressure vessel with a safety factor, since external pressure buckles the shell and insufficient t gives pcr<0.09MPa and collapse, thus accurately calculating the wall thickness and stiffening rings;
2) Fit stiffening rings/strengthening rings on the shell to raise external-pressure stability, since circumferential instability collapses it, thus adding rings resists buckling;
3) Determine t and L/D per the GB/T 150 external-pressure formulas, since not calculating for external pressure leaves it thin, thus taking compliant thickness;
4) Verify by a vacuum test that it does not deform, since the design requirement must be measured, thus pressure-testing to verify the shape;
5) Install a vacuum breaker to prevent abnormal suction collapse, since over-suction collapses it, thus breaking the vacuum preserves the shape;
6) Control shell roundness and angularity, since defects lower the critical pressure, thus controlling shape raises stability;
7) Periodically measure wall thinning, since thinning lowers pcr, thus measuring on schedule;
8) Include external-pressure verification in vessel design, since the original lack of verification is the root cause of collapse, thus the design must include it.
GB/T 150.1-2011 Pressure vessels General requirements