E44-093 · Insufficient Vessel Strength and Wall Thickness · Shell-and-tube heat exchanger tubesheet · ★★
Insufficient expansion rate left the tube ends loose; the per-tube leak rate exceeded the limit and heat transfer efficiency dropped
[Loose Expansion] An expansion rate below specification leaves the joint force insufficient; differential thermal expansion loosens it.
[Calculation] An expansion rate <1% makes the pull-out force < design and the tube end leaks.
[Design Omission] The expansion rate was not controlled and no trial expansion was done, so it loosened and leaked.
1) Control the expansion rate to 1%~1.5%, since an expansion rate <1% makes the pull-out force < design and loosens and leaks the tube end, thus controlling the rate provides sufficient joint force and no leak;
2) Determine process parameters by trial expansion (expand a trial first to fix the rate), since material batches vary, thus trial expansion sets the optimal parameters for batch consistency;
3) Control tubesheet hole roughness (suitable Ra), since a rough hole wall gives strong grip, thus controlling roughness preserves the expansion joint and prevents loosening;
4) Combine expansion and welding to prevent loosening (expand first, then weld), since welding seals and expansion carries load for double protection against loosening, thus no leak over a long cycle;
5) Pressure-test individual tubes to find leaks (pressurize tube by tube), since a single-tube leak is hard to notice and the test pinpoints it, thus confirming each tube's seal;
6) Periodically inspect the tube ends (visual/dye penetrant), since loosening and leakage progress gradually and periodic inspection prevents them, thus maintaining the seal;
7) Verify during commissioning that there is no leak (shell-side/tube-side pressure test), since leakage is the outcome and must be measured, thus acceptance;
8) Include the expansion process in tubesheet design, since the original lack of expansion-rate control caused loosening and leakage, thus fixing the process at the design stage.
GB/T 151-2014 Heat exchangers