E44-144 · Insufficient Vessel Strength and Wall Thickness · Horizontal air receiver (L/D=6) · ★★
Excessive saddle spacing sagged the middle by 12 mm and cracked and leaked the circumferential weld
[Bending Moment] The mid-span bending moment M of the two-saddle beam sags the middle.
[Overstress] σ=M/W exceeds the allowable and cracks the weld.
[Design Omission] The saddle spacing was not calculated and no stiffening rings were fitted, so it sagged.
1) Calculate the mid-span bending moment of the two-saddle beam to verify the wall thickness, since large spacing sags the middle and cracks the weld, thus calculating the moment sets the thickness;
2) Add stiffening rings to reduce the mid-span moment, since sagging comes from an excessive moment, thus adding rings reduces the moment;
3) Lay out the saddle spacing at L/D ≤ the design value, since excessive spacing sags it, thus controlling the spacing;
4) Verify the local stress at the saddle horn bearing area, since concentrated stress cracks it, thus verifying the bearing area;
5) Inspect by NDT after welding for mid-seam cracks, since cracking occurs at the weld, thus inspecting the joint;
6) Keep foundation settlement even to prevent eccentric loading, since eccentric load adds moment, thus even settlement;
7) Measure during commissioning that the mid-span sag ≤ allowable, since the design requirement must be measured, thus confirming at delivery;
8) Include the saddle calculation in vessel design, since the original lack of calculation is the root cause of sagging, thus the design must include it.
GB/T 150.1-2011 Pressure vessels General requirements