E44-145 · Insufficient Vessel Strength and Wall Thickness · Autoclave (10MPa) · ★★★
Uneven bolt preload left the local sealing contact pressure insufficient; the gasket blew out and the media leaked
[Uneven Preload] Differences in bolt force make the sealing surface contact pressure uneven.
[Failure] Where the local contact pressure < required it leaks and the gasket blows out.
[Design Omission] No preload to a uniform torque and no controlled tightening sequence, so it failed.
1) Preload the bolts to a uniform torque per the sealing contact pressure, since uneven preload leaves the local contact pressure insufficient and leaks, thus even force preserves the seal;
2) Tighten in a symmetric, staged sequence, since a disordered sequence causes bias, thus even staged tightening;
3) Select a temperature- and pressure-resistant gasket and control its compression rate, since the gasket blew out, thus compliant gasket selection;
4) Verify bolt strength and count, since insufficient force leaks, thus verifying the count provides sufficient force;
5) Check flange face flatness and finish, since face damage leaks, thus checking the faces;
6) Raise pressure in stages and check for leaks, since a sudden rise causes leakage, thus staged verification;
7) Verify during commissioning that it holds pressure without leakage, since the design requirement must be measured, thus confirming at delivery;
8) Include the preload procedure in assembly, since the original lack of even tightening is the root cause of failure, thus a process constraint.
GB/T 150.3-2011 Pressure vessels - Design