E44-195 · Insufficient Vessel Strength and Wall Thickness · High-pressure separator shell · ★★★
Weld seams were not inspected; defects propagated and cracked and leaked the shell, halting production
[Defect] Weld defects were not detected, allowing them to propagate.
[Crack] Propagation led to a through-wall crack.
[Design Omission] No scheduled inspection and no NDT, so it cracked.
1) Perform NDT inspection on vessel welds per code, since undetected defects propagate and crack and leak, thus inspection stops defect propagation;
2) Set up scheduled inspection to re-check defects, since they propagate gradually, thus scheduled testing;
3) Apply post-weld heat treatment to relieve stress, since residual stress promotes propagation, thus heat treatment;
4) Select material with controlled sulfur and phosphorus to reduce cracking sensitivity, since impurities promote cracking, thus controlling material;
5) Install leak monitoring and alarms, since cracking is detectable, thus monitoring and alarming;
6) Provide overpressure relief protection, since cracking accompanies overflow, thus relief;
7) Verify during commissioning that pressure holds with no defects, since the design requirement must be measured, thus confirming at delivery;
8) Include inspection in vessel fabrication, since the original lack of inspection is the root cause of the defect, thus fabrication must include it.
NB/T 47013 Non-destructive testing of pressure equipment