Knowledge Base › Fluid Systems Error Case › Air Lock Vibration in a Siphon Pipe

Air Lock Vibration in a Siphon Pipe

E44-951 · Siphon and Backflow · Siphon Pipe · ★★

Problem Description

Air lock, vibration, break

Root Cause

[Mechanism] A closed air-lock cavity forms locally at the elbow of the siphon pipe; the fluid striking the air cavity induces resonance in the piping, reducing the flow and stopping it.
[Calculation] The elbow air cavity is 0.5 L, the excitation frequency of 12 Hz coincides with the pipe natural frequency of 12 Hz, the amplitude of 0.4 mm exceeds the 0.15 mm limit, and the flow drops by 50%.
[Design Omission] The elbow air was not vented, the routing was not changed, and no resonance check was performed.

Corrective Solution

1) Install a vent valve at the high point of the elbow (venting the air cavity, rate ≥0.3 m³/h), because the closed air cavity is the vibration source and venting eliminates it, thereby removing the source;
2) Change the elbow routing to avoid air pockets (reducing the air cavity volume by 80%), because a smaller air cavity weakens the vibration and rerouting suppresses it, thereby reducing vibration;
3) Check the natural frequency of the piping (shifting it away from 12 Hz to ≥15 Hz), because resonance amplifies vibration and shifting the frequency makes it safe, thereby avoiding resonance;
4) Add supports to the elbow to limit displacement (clearance ≤2 mm), because vibration transmits displacement and the supports suppress it, thereby limiting the amplitude;
5) Stabilize the inlet flow to reduce pulsation (insertion loss ≥10 dB(A)), because pulsation excites vibration and flow stabilization reduces it, thereby reducing the excitation;
6) Perform a resonance test (measuring the amplitude ≤0.15 mm), because the design omitted the frequency check and the test confirms whether resonance exists, thereby determining the avoided frequency from data;
7) Monitor the amplitude and flow in operation (alarm if vibration >0.15 mm or drop >20%), because resonance first shows as amplitude before flow stoppage, thereby monitoring vibration for early warning;
8) Write venting and frequency avoidance into the installation card, because the root cause of the air lock is accumulated air at the elbow without a frequency check, so the installation must govern to prevent vibration and stoppage.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping