E44-1054 · Two-Phase Flow and Air Binding · Pump · ★★★
Air binding, run-dry, no delivery
[Mechanism] The pump was not primed and air accumulated inside; the impeller spins dry without delivering liquid, and the mechanical seal runs dry.
\n[Calculation] 0.5L of air trapped at the pump inlet, Q=0 after startup, seal-chamber temperature rise 40℃, leakage after 5min of dry running.
\n[Design Omission] Pump not primed, inlet air not vented, no foot valve fitted.
1) Prime the pump and vent air (bleed the high point of the inlet until full of liquid); since air occupying the casing causes run-dry, full priming restores liquid delivery;
\n2) Fit vent valves at high points (vent before startup); since air causes run-dry, venting fills the casing, restoring normal operation;
\n3) Fit a foot valve (keeps the inlet flooded); since backflow causes run-dry, the foot valve keeps the inlet flooded, holding the liquid;
\n4) Raise inlet pressure (lower the installation height); since low inlet pressure causes run-dry, raising the pressure protects the pump, suppressing dry running;
\n5) Run a startup test (Q≥rated, seal temperature rise ≤10℃); since run-dry was never verified, measured data confirms normal operation, so operation is confirmed by data;
\n6) Install flow and temperature monitoring (trip on run-dry); since run-dry first appears as zero flow, early detection gives warning, so dry running is monitored and alerted;
\n7) Enforce the priming procedure in operation (prime before every start); since skipped priming causes run-dry, the controlled procedure keeps startup safe, preventing dry running in operation;
\n8) Write priming and venting into the process sheet; since the root cause of air binding is unprimed, unvented startup, the process stage provides the check.
GB/T 5657-1995 Technical specifications for centrifugal pumps