Knowledge Base › Fluid Systems Error Case › Air Binding Causing Pump Run-Dry

Air Binding Causing Pump Run-Dry

E44-1054 · Two-Phase Flow and Air Binding · Pump · ★★★

Problem Description

Air binding, run-dry, no delivery

Root Cause

[Mechanism] The pump was not primed and air accumulated inside; the impeller spins dry without delivering liquid, and the mechanical seal runs dry.
\n[Calculation] 0.5L of air trapped at the pump inlet, Q=0 after startup, seal-chamber temperature rise 40℃, leakage after 5min of dry running.
\n[Design Omission] Pump not primed, inlet air not vented, no foot valve fitted.

Corrective Solution

1) Prime the pump and vent air (bleed the high point of the inlet until full of liquid); since air occupying the casing causes run-dry, full priming restores liquid delivery;
\n2) Fit vent valves at high points (vent before startup); since air causes run-dry, venting fills the casing, restoring normal operation;
\n3) Fit a foot valve (keeps the inlet flooded); since backflow causes run-dry, the foot valve keeps the inlet flooded, holding the liquid;
\n4) Raise inlet pressure (lower the installation height); since low inlet pressure causes run-dry, raising the pressure protects the pump, suppressing dry running;
\n5) Run a startup test (Q≥rated, seal temperature rise ≤10℃); since run-dry was never verified, measured data confirms normal operation, so operation is confirmed by data;
\n6) Install flow and temperature monitoring (trip on run-dry); since run-dry first appears as zero flow, early detection gives warning, so dry running is monitored and alerted;
\n7) Enforce the priming procedure in operation (prime before every start); since skipped priming causes run-dry, the controlled procedure keeps startup safe, preventing dry running in operation;
\n8) Write priming and venting into the process sheet; since the root cause of air binding is unprimed, unvented startup, the process stage provides the check.

Checklist

Reference

GB/T 5657-1995 Technical specifications for centrifugal pumps