E44-412 · Two-Phase Flow and Gas Binding · Branch Pipe Gas-Liquid Distribution · ★★
Uneven gas-liquid mixing makes the two branch flows diverge by ±20%, and one branch carries excess gas and cavitates.
[Mechanism] Poor mixing makes the gas-liquid ratio differ between branches, and the flow diverges.
[Calculation] The ±20% divergence makes one branch cavitate.
[Design Omission] No mixer was fitted and the branches were not laid out symmetrically — the cause of the mal-distribution.
1) Fit a static mixer ahead of the branches to homogenize the flow; uneven mixing gives ±20% divergence and branch cavitation, so mix it evenly;
2) Make the two branches symmetric, equal in diameter and length; asymmetry causes divergence, so keep them symmetric;
3) Fit a flow meter on each branch to monitor divergence; imbalance is hard to detect, so monitor it;
4) Balance with branch valves; divergence needs tuning, so balance it;
5) Keep the inlet gas fraction steady; varying gas shifts the balance, so control the gas;
6) Add downstream gas collection to keep a single branch from carrying gas; gas carry-over cavitates, so collect the gas;
7) Periodically check the branch flows; drift causes divergence, so recheck them;
8) Write mixing and symmetry into the design; the original unevenness was the root cause of divergence, so gate it at design stage.
GB/T 5657-2013 Technical specifications for centrifugal pumps