E44-551 · Heat Exchanger Fouling and Insufficient Heat Transfer · Coking Heat Exchanger - Tube · ★★
Coke deposits, blockage, K drops, short run cycle
[Mechanism] High-temperature coke deposits on the walls.
[Calculation] Excessive wall temperature causes coking, Rf=0.5, K drops by 45%, and the run cycle shortens.
[Design Omission] No wall-temperature control and no decoking were provided, causing coking.
1) Control wall temperature (≤ thermal cracking point of coke precursors) to prevent coking; because excessive wall temperature causes coke deposition, Rf=0.5 drops K by 45% and shortens the run cycle, temperature control suppresses coking and maintains rated flow;
2) Schedule mechanical decoking (every 2000 h of operation); because hardened coke adheres strongly and is hard to remove online, periodic mechanical decoking restores the flow area;
3) Add K monitoring (alarm when K drops by 10%); because coke deposition first lowers K before the run cycle collapses, monitoring K gives early warning and guides decoking;
4) Raise flow velocity (≥1.5 m/s) to prevent stagnation; because long residence in low-velocity zones and wall temperature rise promote coking, higher velocity reduces residence time and suppresses coking;
5) Even out heating to prevent local hot spots (switch to helical baffles / zoned temperature control); because local overheating is the source of coke deposition and uneven temperature promotes bypass flow, even heating eliminates hot spots;
6) Use heat-resistant materials (316L / aluminized); because ordinary carbon steel has low heat resistance and over-temperature oxidation and scaling promote coking, heat-resistant material extends life and suppresses coking;
7) Schedule coke-thickness inspection (infrared / borescope each quarter); because the coke layer gradually thickens and worsens the K drop and cycle shortening, quantitative coke-thickness measurement guides decoking;
8) Write wall-temperature control and decoking into the coking heat-exchange procedure; because the original design omitted wall-temperature control and decoking, the root cause of coking, the procedure enforces control.
GB/T 151-2014 Heat exchangers