E44-430 · Two-Phase Flow and Gas Binding · Pump Priming Not Fully Vented · ★★
Gas trapped in the pump casing cannot be fully bled during priming; on start-up the pump still runs dry, needs repeated priming, and fails to start.
[Mechanism] Gas trapped at the top of the casing cannot be fully bled, so it will not prime full.
[Calculation] On start-up it still runs dry and needs repeated priming.
[Design Omission] No top vent was fitted and priming was not completed — the cause of the difficult priming.
1) Fit a vent valve at the top of the casing and bleed it fully during priming; trapped gas defeats priming, leaves the pump dry on start-up and needs repeated priming, so vent at the top to prime fully;
2) Prime until overflow is steady before starting; if not full it runs dry, so prime to overflow;
3) Fit a foot valve at the suction to keep liquid in; internal leakage leaves it empty, so use a foot valve;
4) Check the priming-full condition; if not full it runs dry, so verify fullness;
5) Mount the pump low to prevent suction loss; a high mount is hard to prime, so keep it low;
6) Periodically test-start to check for dry running; it develops gradually, so test-start;
7) Provide a vacuum priming aid; a high mount is hard to prime, so use vacuum priming;
8) Write priming venting into the procedures; the original trapped gas was the root cause of the difficulty, so gate it in the procedures.
GB/T 5657-2013 Technical specifications for centrifugal pumps