Knowledge Base › Fluid Systems Error Case › Anchor Support Failure and Shift

Anchor Support Failure and Shift

E44-785 · Piping Supports and Thermal Expansion · Anchor support · ★★★

Problem Description

Anchor support loosened, pipe shifted >20mm, system unstable

Root Cause

[Mechanism] Anchorage failure of the fixed support shifts the piping system.
[Calculation] The lost resistance shifts the pipe >20mm and imposes additional force on the adjacent equipment nozzle.
[Design Omission] The support was neither welded securely nor its load capacity verified — so it must be anchored.

Corrective Solution

1) Re-secure the support and weld the anchor solid (double-sided weld on the anchor plate, leg ≥6mm): because the original loosening shifted the pipe >20mm and destabilized the system, anchoring steadies the system;
2) Verify the anchor's load capacity (size the anchoring force at pipe weight + blind-flange force, ≥1.5×): because a weak anchor shifts and verifying makes it sufficient, the force is verified to carry the thrust;
3) Weld the anchor solid (chemical anchors with shear capacity ≥ design): because loose shifts and welded holds, welding fixes the position;
4) Add a thrust pier (a concrete pier to carry the blind-flange force): because thrust shifts and a pier stops it, the thrust is stopped;
5) Monitor the anchor condition (displacement markers, alarm above >5mm): because gradual shifting cracks the equipment nozzle and early awareness helps, the anchor is monitored;
6) Run a thrust test (pressurize and record the support displacement): because the original lack of testing left the failure undiscovered and the test reveals the load capacity, the thrust is verified;
7) Control the thermal displacement (add compensation on the adjacent run to absorb the growth): because expansion pushes and compensation eases it, the displacement is controlled;
8) Write the anchoring and welding into the assembly card: the original lack of anchoring was the root cause of the failure, so assembly controls it and the position does not drift.

Checklist

Reference

GB/T 17116.1-2018 Pipe supports and hangers