E44-823 · Piping Supports and Thermal Expansion · Pump Discharge · ★★
Pump discharge vibration, support loosening, cracking
[Mechanism] Pulsation at the pump discharge makes the pipe vibrate.
[Calculation] Discharge pulsation drives the amplitude >0.3mm and loosens and cracks the supports.
[Design Omission] Neither securing nor vibration reduction was provided — so securing must be added.
1) Secure the pump discharge supports (densify + weld firmly to carry the pulsation): because the original discharge pulsation drove the amplitude >0.3mm and loosened and cracked the supports, securing the supports reduces vibration;
2) Add discharge damping (dampers increase resistance): because vibration loosens and damping suppresses it, damping is added;
3) Check the support spacing (set the span by the blade frequency): because sparse supports vibrate and the check densifies them, the spacing is checked;
4) Avoid the blade frequency (keep the support span ≥20% away from the blade frequency): because resonance amplifies vibration and avoidance stabilizes it, the frequency is avoided;
5) Monitor the vibration condition (measure the amplitude spectrum, alarm >0.2mm): because progressive vibration brings cracking closer and early awareness helps, vibration is monitored;
6) Perform a vibration test (start up and record the discharge amplitude): because the original lack of testing left the loosening undiscovered, the test identifies the vibration points, so the test is run;
7) Keep the speed stable (keep the speed away from critical): because a changing duty vibrates and control relieves it, the speed is controlled;
8) Write the support securing and damping into the maintenance card: the original lack of securing was the root cause of the discharge issue, so maintenance controls the work and the discharge is stable.
GB/T 17116.1-2018 Pipe supports and hangers