E44-824 · Piping Supports and Thermal Expansion · Support Spacing · ★★
Uneven support spacing, vibration, loosening
[Mechanism] Uneven support spacing makes a local span too large and vibrate.
[Calculation] Uneven spacing can make a span >1.5 times the design value, with amplitude >0.2mm.
[Design Omission] The spacing was neither calculated nor evened out — so it must be calculated.
1) Calculate the spacing and distribute the supports evenly (set a uniform span by deflection / vibration frequency): because the original uneven spacing could make a span >1.5 times the design value with amplitude >0.2mm, even spacing reduces vibration;
2) Check that the spacings are consistent (span difference ≤10%): because a difference causes vibration and the check evens it out, the spacing is checked;
3) Add supports to sparse sections (add supports in sparse sections to reduce the span): because sparse supports vibrate and added supports densify them, densification is applied;
4) Increase pipe stiffness (switch to a thicker wall to reduce the amplitude): because a soft pipe vibrates and raising stiffness hardens it, the stiffness is increased;
5) Monitor the vibration condition (measure the amplitude of each span, with alarms): because progressive vibration loosens parts and early awareness helps, vibration is monitored;
6) Perform a load test (start up and check the vibration): because the original lack of testing left the vibration undiscovered, the test identifies the vibration points, so the load test is run;
7) Control the excitation source (keep the speed away from critical): because the source causes vibration and control relieves it, the source is controlled;
8) Write the spacing calculation and even distribution into the calculation sheet: the original design omission was the root cause of the spacing, so calculation controls the design and the spacing is even.
GB/T 17116.1-2018 Pipe supports and hangers