E44-822 · Piping Supports and Thermal Expansion · Compressor Discharge · ★★★

Problem Description

Compressor discharge vibration, support loosening, cracking

Root Cause

[Mechanism] Pulsation at the compressor discharge makes the pipe vibrate.
[Calculation] Discharge pulsation drives the amplitude >0.4mm and disturbs and cracks the adjacent equipment.
[Design Omission] Neither securing nor vibration reduction was provided — so securing must be added.

Corrective Solution

1) Secure the discharge supports against vibration (densify + weld firmly to carry the pulsation): because the original discharge pulsation drove the amplitude >0.4mm and disturbed and cracked the adjacent equipment, securing the supports reduces vibration;
2) Add a buffer vessel to stabilize the flow (fit a buffer vessel at the discharge to cut the pulsation): because pulsation vibrates and buffering stabilizes it, buffering is added;
3) Check the support spacing (set the span by the blade-pass frequency): because sparse supports vibrate and the check densifies them, the spacing is checked;
4) Avoid the blade frequency (adjust the support span ≥20% away from the blade frequency): because resonance amplifies vibration and avoidance stabilizes it, the frequency is avoided;
5) Monitor the vibration condition (measure the amplitude spectrum, alarm >0.3mm): because progressive vibration brings cracking closer and early awareness helps, vibration is monitored;
6) Perform a vibration test (start up and record the discharge amplitude): because the original lack of testing left the loosening undiscovered, the test identifies the vibration points, so the test is run;
7) Keep the speed stable (keep the speed away from critical): because a changing duty vibrates and control relieves it, the speed is controlled;
8) Write the support securing and buffering into the maintenance card: the original lack of securing was the root cause of the discharge issue, so maintenance controls the work and the discharge is stable.