E44-907 · Siphon and Backflow · Siphon Pipe · ★★
Fluctuation, instability, stoppage
[Mechanism] The siphon flow fluctuates with the inlet level, and the changing liquid-column length makes the vacuum vary, so the flow becomes unstable.
[Calculation] An inlet level fluctuation of ±0.3 m causes h_v to fluctuate by ±0.3 m and the flow by ±12%; without damping the risk of flow stoppage is high.
[Design Omission] No surge vessel, no buffer tank, and no flow-velocity control.
1) Install a surge tank at the inlet (volume ≥5× the pipe volume), because the level fluctuation is transmitted directly to the vacuum and a large tank volume absorbs it and steadies the flow, thereby suppressing fluctuation and preventing stoppage;
2) Add a buffer tank (air volume ≥ pump flow ×10 s), because the air cushion absorbs and stores energy and damps the flow pulsation, cutting the amplitude from ±12% to ±3%, thereby steadying the flow;
3) Enlarge the inlet pipe (DN150→DN200) to lower the velocity to 1.2 m/s, because at low velocity the level fluctuation has less effect on the vacuum, thereby reducing sensitivity;
4) Install a control valve at the outlet closed-loop on the vacuum (PID), because the vacuum fluctuation precedes the flow fluctuation and the loop steadies it, thereby controlling the vacuum to steady the flow;
5) Add a vacuum gauge at the high point with a fluctuation alarm (alarm on fluctuation >±0.5 m), because the fluctuation exceeding the limit precedes a stoppage, allowing early intervention, thereby monitoring the fluctuation to prevent stoppage;
6) Run a fluctuation test (step the level and check the flow recovers), because the design missed the damping and the test confirms the buffer capacity is sufficient, thereby setting the tank volume on data;
7) Keep the velocity at 1.2–1.5 m/s to prevent air accumulation (fluctuation promotes gas release), because steady flow carries little air while fluctuation generates vortices that entrain it, thereby controlling the velocity to steady the suction;
8) Write the surge tank and buffer into the siphon design specification, because the root cause of fluctuation is no damping and no control, thereby the specification controls it to prevent stoppage.
GB/T 20801.3-2020 Design code for industrial metallic piping