Knowledge Base › Fluid Systems Error Case › Multi-Nozzle Flow Deviation

Multi-Nozzle Flow Deviation

E44-729 · Uneven Flow Distribution · Nozzle · ★★

Problem Description

Nozzle variation, flow difference

Root Cause

[Mechanism] A nozzle difference makes the flows vary.
[Calculation] An orifice difference causes the variation.
[Design Omission] No standardization of the orifices, no verification, and no inspection were provided, so the orifices differ.

Corrective Solution

1) Standardize the nozzle orifice diameter (same diameter on each nozzle, tolerance ±0.02mm), because the original orifice difference made the flows differ by >8% and vary, thereby standardizing the orifices and evening the flow;
2) Verify the flow of each nozzle (calibrate, deviation ≤3%), because a difference makes the flows vary and verification restores accuracy, thereby verifying the flows;
3) Raise the machining precision (polish the nozzle bore to Ra0.4), because a deviation means a difference and precision prevents it, thereby raising the precision;
4) Clean the nozzles against blockage (clean at fixed intervals, remove coke), because blockage makes the flows vary and cleaning restores flow, thereby cleaning the nozzles;
5) Monitor the nozzle condition (measure the spray angle, replace on any deviation), because gradual deviation is invisible and monitoring catches it, thereby giving early warning;
6) Run a spray test (observe the spray pattern, accept when even), because the lack of testing caused the variation and testing verifies it, thereby testing the spray;
7) Keep the pressure steady (nozzle inlet pressure fluctuation ≤2%), because changing conditions cause variation and control steadies them, thereby steadying the pressure;
8) Write the orifice standardization and flow verification into the specification (spray-angle tolerance), because the missing standardization was the root cause of the orifice difference and freezing it into the specification enforces control.

Checklist

Reference

GB/T 2624.1-2006 Flow measurement

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL