Knowledge Base › Fluid Systems Error Case › Orifice Plate Maldistribution

Orifice Plate Maldistribution

E44-728 · Uneven Flow Distribution · Orifice plate · ★★

Problem Description

Plate maldistribution, β difference

Root Cause

[Mechanism] A difference between the plates makes the distribution uneven.
[Calculation] A β difference causes the uneven distribution.
[Design Omission] No standardization of β, no verification, and no inspection were provided, so β differs.

Corrective Solution

1) Standardize the orifice-plate β value (each plate β = 0.5 ±0.01), because the original β difference made the flows differ by >10% and the distribution uneven, thereby standardizing β and evening the flow;
2) Verify the orifice-plate flow (calibrate each plate, deviation ≤2%), because a difference makes the distribution uneven and verification restores accuracy, thereby verifying the flows;
3) Raise the machining precision (orifice diameter tolerance ±0.05mm), because a deviation means a difference and precision prevents it, thereby raising the precision;
4) Clean the orifices against blockage (clean at fixed intervals, remove scale), because blockage makes the distribution uneven and cleaning restores flow, thereby cleaning the orifices;
5) Monitor the plate condition (measure the orifice diameter, replace on wear), because gradual deviation is invisible and monitoring catches it, thereby giving early warning;
6) Perform calibration (standard meter, build a curve), because the lack of calibration caused the difference and calibration restores accuracy, thereby calibrating;
7) Keep the medium steady (temperature and pressure compensation), because changing conditions cause a difference and control steadies them, thereby steadying the medium;
8) Write the β standardization and flow verification into the specification (β tolerance), because the missing standardization was the root cause of the β difference and freezing it into the specification enforces control.

Checklist

Reference

GB/T 2624.2-2006 Orifice-plate flowmeters