E44-250 · Pump Selection & Cavitation · Highland centrifugal pump IS100-65-200 · ★★★
The installation altitude was 3000m where the atmospheric pressure is only 0.70atm (the pump had been selected on the 1atm standard), NPSHa actually fell by about 3m and the pump cavitated
[Cavitation] The low atmospheric pressure at high altitude reduces the Pa/ρg term of NPSHa, so a selection made on standard atmospheric pressure is optimistic and cavitation occurs.
[Calculation] At 3000m Pa is about 70kPa against the standard 101kPa, a reduction of 31kPa; Pa/ρg falls by about 3.2m and NPSHa is seriously insufficient.
[Design Omission] The selection did not check NPSHa against the actual local atmospheric pressure, so cavitation occurred at altitude.
1) Check NPSHa against the actual local atmospheric pressure (with an altitude correction), because Pa is low at altitude, thereby making the design realistic;
2) Select a pump type with a lower NPSHr to compensate for the loss of Pa, because the margin is tight, thereby covering the boundary case;
3) Increase the suction submergence depth to raise NPSHa, because the greater submergence raises NPSHa, thereby compensating for the low Pa;
4) Fit an inducer to lower NPSHr, because the inducer raises the inlet pressure, thereby making the pump suitable;
5) Shorten and enlarge the suction line to reduce the loss, because hf consumes NPSHa, thereby reducing the loss;
6) Control the medium temperature to lower Pv, because Pv also consumes NPSHa, thereby improving the result further;
7) Measure the inlet pressure on site during commissioning to confirm there is no cavitation, because the design requirement must be verified by measurement, thereby closing out the acceptance;
8) Incorporate the altitude correction for atmospheric pressure into the selection, because selecting on the standard value was the root cause, so the design must include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH