Incorrect slope of the suction line traps gas and causes cavitation

E44-251 · Pump Selection & Cavitation · Horizontal suction pump IS65-50-160 · ★★

Problem Symptom

The suction line sloped the wrong way (downward toward the pump) so the gas could not escape back to the tank; gas collected ahead of the pump, causing an air lock on start-up and cavitation in operation

Root Cause

[Cavitation] The reverse slope prevents bubbles from escaping back to the suction tank; they gather ahead of the pump forming an air lock and cavitation.
[Calculation] On a reverse slope the buoyancy of the bubbles opposes the flow direction and the gas collects at the high point at the pump inlet, where the gas slug enters the impeller, collapses and cavitates.
[Design Omission] The suction line was not laid out with a slight rise from the tank to the pump, so the reverse slope trapped gas.

Correct Solution

1) Re-slope the suction line with a slight rise from the tank toward the pump (slope ≥0.5%), because the slope lets the gas escape back to the tank, thereby eliminating the accumulation;
2) Fit an air vent valve at the high point where the slope cannot be changed, because the high point collects gas, thereby venting it;
3) Avoid local low dips that collect liquid and local high humps that collect gas in the suction line, because the geometry stagnates the gas, thereby keeping the flow smooth;
4) Vigorously purge the line before start-up, because residual gas causes the air lock, thereby achieving a fully vented line;
5) Install inlet pressure monitoring to detect the air lock, because the air lock causes an abnormal pressure, thereby enabling diagnosis;
6) Use a sufficiently large suction pipe diameter to reduce the velocity so the gas travels with the liquid, because low velocity carries the gas, thereby aiding venting;
7) Verify during commissioning that start-up is smooth and there is no cavitation in operation, because the design requirement must be verified by measurement, thereby closing out the acceptance;
8) Incorporate the suction line slope into the design, because the original reverse slope was the root cause, so the design must include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH