E44-878 · Throttling Noise and Vibration · Bypass valve · ★★
Bypass valve throttled at Δp1.5MPa with jet noise 90dB(A)
[Mechanism] The bypass valve throttles a large pressure drop, and the jet radiates noise.
[Calculation] Outlet v=√(2Δp/ρ)≈45m/s, noise 90dB(A).
[Design Omission] No low-noise model selected, no silencing, no use restriction.
1) Select a low-noise bypass (low-noise bypass valve + silencing), since the original Δp1.5MPa jet noise was 90dB(A), thus the selection cuts noise;
2) Verify the sound level (outlet ≤85dB(A)), since exceeding it disturbs and verification meets it, thus verifying sound;
3) Add a silencer (resistive, insertion loss ≥12dB), since the bare valve radiates 90dB(A) and silencing lowers it, thus silencing;
4) Restrict the throttling duty (bypass for standby only, main line regulates flow), since misuse makes noise and restriction stops it, thus restricting use;
5) Monitor the noise (sound-level meter, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring noise;
6) Run an acoustic test (measure Lw), since the lack of testing left the noise undetected and the test reveals the level, thus testing sound;
7) Control the opening to steady it (operate ≥30%), since changing conditions make noise and control steadies it, thus controlling the opening;
8) Write the model selection and silencing into the specification, since the original lack of selection is the root cause of noise and locking it in closes the loop, thus controlling it in the spec.
GB/T 17213.1-2015 Industrial-process control valves