Knowledge Base › Fluid Systems Error Case › Magnetic Filter Failure

Magnetic Filter Failure

E44-1060 · Filter Clogging and Fouling · Magnetic Filter · ★★

Problem Description

Magnetism loss, ferrous debris, fouling

Root Cause

[Mechanism] The magnetic core loses field strength or the magnetic circuit shorts out, so ferrous debris is not captured and enters downstream equipment.
[Calculation] The core flux dropped from 0.8T to 0.3T, ferrous debris capture fell from 95% to 40%, and downstream pumps stuck 2 times.
[Design Omission] The magnetic core was not replaced, field strength was not verified, and no cleaning interval was set.

Corrective Solution

1) Replace with a strong core (NdFeB 1.2T to replace the weakened magnet), since weak magnetism lets debris through and a new magnet captures it, thus stopping debris;
2) Verify field strength (≥0.8T capture threshold), since weak magnetism passes debris and checking it ensures capture, thus maintaining adsorption;
3) Set a cleaning interval (remove ferrous debris weekly), since buildup passes debris and cleaning restores cleanliness, thus protecting downstream;
4) Lower and stabilize the flow velocity (v≤1.5m/s), since high velocity defeats capture and slowing it allows adsorption, thus retaining debris;
5) Run a capture test (ferrous debris ≤1%), since debris went unverified and measurement confirms cleanliness, thus sizing capture by data;
6) Fit downstream ferrous-debris monitoring (alarm on exceedance), since debris first shows as iron and early notice gives warning, thus alarming on debris;
7) Keep the medium clean in operation (remove large iron upstream), since heavy debris weakens the magnet and cleanliness protects it, thus preventing debris in service;
8) Write magnet replacement and field verification into the specification, since the root cause of magnetic-filter failure was core decay without field verification, thus controlling to spec.

Checklist

Reference

HG/T 21637-1991 Chemical-industry piping filters