E44-1061 · Filter Clogging and Fouling · Filter · ★★
Shell liquid pooling, clogging, pressure drop
[Mechanism] Liquid pools at the bottom of the filter shell, debris settles and cakes up, the flow area shrinks, and pressure drop rises.
[Calculation] 15L of sludge at the shell bottom, the effective flow area shrank by 30%, ΔP rose by 0.18MPa, and flow velocity dropped by 20%.
[Design Omission] No bottom drain was fitted, the slope was not checked, and no liquid was drained.
1) Fit a drain valve at the shell bottom (DN25, drained periodically), since pooling shrinks the area and draining restores it, thus lowering pressure drop;
2) Check the shell slope (1:50 in the flow direction for draining), since a reversed slope causes pooling and correcting it drains the liquid, thus preventing accumulation;
3) Add a drain at the lowest point, since accumulation clogs and draining clears it, thus removing liquid;
4) Raise and stabilize the flow velocity (v≥1.5m/s to flush sludge), since low velocity lets sludge settle and raising it flushes it, thus suppressing accumulation;
5) Run a flow test (ΔP≤0.1MPa), since accumulation went unchecked and measurement confirms flow, thus sizing pressure drop by data;
6) Fit level/pressure monitoring (alarm on pooling), since accumulation first shows as rising pressure and early notice gives warning, thus alarming on accumulation;
7) Control the draining interval in operation (drain weekly), since delay causes pooling and scheduled draining prevents it, thus avoiding accumulation in service;
8) Write draining and slope checking into the calculation sheet, since the root cause of shell pooling was no drain and a reversed slope, thus controlling by calculation.
HG/T 21637-1991 Chemical-industry piping filters