Magnetic Filter Saturated Without Cleaning

E44-459 · Filter Clogging and Contamination · Magnetic Filter Permanent Magnet · ★★

Problem Description

The magnetic rods saturated with iron chips and were not cleaned; magnetic force decayed, downstream iron-chip concentration reached 0.3% > 0.05%, and the pump impeller was scored.

Root Cause

[Mechanism] Once the rods are saturated, newly arriving iron chips are not captured and pass with the flow.
[Calculation] Per-rod chip capacity M=50g; accumulated 80g exceeds capacity, collection efficiency drops from 98% to 30%, and outlet reaches 0.3%.
[Design Omission] No chip-removal interval was set and no magnetic-strength monitoring existed; saturation caused capture failure.

Corrective Solution

1) Set chip removal every shift based on the 50g capacity, because the original 80g exceeded capacity, efficiency was 30% and outlet was 0.3%, thereby removing on schedule to restore capture;
2) Periodically measure rod strength and replace below threshold, because decay causes capture loss, thereby measuring magnetism;
3) Provide two rod banks for rotation and cleaning, because cleaning otherwise cuts flow, thereby rotating;
4) Add a non-magnetic fine filter downstream as a backup, because escaped chips damage the pump, thereby providing a backstop;
5) Record chip weight on removal and track the trend, because falling weight indicates degradation, thereby logging weight;
6) Reduce rod spacing to within a few rod diameters, because wide spacing leaves bypass gaps, thereby packing them densely;
7) Add a settling tank at the inlet to settle large chips first, because large chips consume capacity, thereby settling first;
8) Write chip removal into the shift inspection, because the original lack of removal is the root cause of saturation, thereby enforcing shift inspection.

Checklist

Reference

GB/T 17486-2006 Hydraulic fluid power filters

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL