E44-314 · Excessive Pipe Resistance and Pressure Drop · Heavy-oil transfer at viscosity ν=200cSt · ★★★
At Re=vd/ν=320<2000 the flow is laminar, and λ=64/Re=0.2 makes hf ten times the turbulent value, leaving the pump pressure insufficient.
[Laminar] High viscosity drives Re<2000, and λ=64/Re spikes.
[Added Resistance] Laminar hf is ten times the turbulent value, leaving the pump under-pressured.
[Design Omission] No heating to cut viscosity and no upsizing of the bore — high-viscosity resistance.
1) Trace-heat the oil to raise its temperature and drop ν to 50cSt and lift Re, since the original ν=200 gave Re=320 (laminar), λ=0.2, and 10× hf — thus cutting viscosity to raise Re;
2) Enlarge the bore to lower v and lift Re out of laminar range, since low v means low Re — thus upsizing;
3) Check hf with the laminar λ=64/Re, since a turbulent λ undercounts the loss — thus sizing it correctly;
4) Choose a higher-head pump to cover the laminar loss, since the heavy loss needs pressure — thus going high-head;
5) Keep straight runs short to cut L and total hf, since laminar loss accumulates with L — thus laying it out short;
6) Use a shear-thinning pump (progressive cavity), since high viscosity suits screw pumps — thus swapping the pump;
7) Insulate against cooling that raises viscosity, since cold thickens the oil — thus keeping it warm;
8) Write the viscosity-temperature behavior into the design, since the unchecked viscosity was the root cause — thus locking it in at design.
GB/T 20801.3-2020 Design code for industrial metallic piping