E44-306 · Excessive Pipe Resistance and Pressure Drop · A J41H globe valve held at 40% opening · ★★
Half-opening the valve raises its local-loss coefficient ζ from 8 to 22, drops pressure by 0.2MPa, and raises pump power draw by 18%.
[Throttling] Half-opening shrinks the flow area and spikes ζ.
[Energy Waste] Δp=ζρv²/2 makes the pump burn extra power.
[Design Omission] The valve was not run fully open and no bypass was used for control — throttling loss at the valve.
1) Run the main valve fully open in normal operation and use a bypass to trim flow, since half-opening at ζ=22 gives Δp=0.2 and +18% power — thus opening fully to cut ζ;
2) Put a dedicated control valve where trimming is needed, since a half-open globe valve loses heavily — thus controlling with a proper valve;
3) Add a flow meter to monitor throttling loss, since hidden loss is hard to detect — thus watching the loss;
4) VFD-drive the pump to follow load, since fixed-speed throttles away power at the valve — thus varying the speed;
5) Check the fully-open ζ with margin, since half-open is off the design point — thus designing for full opening;
6) Periodically check valve opening to prevent accidental half-open, since human error is likely — thus inspecting the setting;
7) Use multi-stage pressure reduction for large differential pressure, since a single throttling valve loses heavily — thus staging the drop;
8) Write the operating opening into the procedure, since the original half-open was the root cause of wasted energy — thus locking it in by procedure.
GB/T 20801.3-2020 Design code for industrial metallic piping