E44-307 · Excessive Pipe Resistance and Pressure Drop · A DN100 bore suddenly expanding to DN200 · ★★
Sudden enlargement creates a local loss hj=ζ(v1²-v2²)/2g=0.05MPa, 60% of that segment's loss, dropping downstream pressure.
[Sudden Enlargement] The abrupt area change separates the flow and forms eddies, causing heavy loss.
[Loss] hj=ζ(v1²-v2²)/2g, and ζ rises with the expansion ratio.
[Design Omission] No diffuser and no sudden-enlargement check — heavy loss at the abrupt step.
1) Replace it with a diffuser of cone angle ≤15°, since sudden enlargement has a high ζ and hj=0.05 (60% of loss) — thus diffusing to cut ζ;
2) Check the sudden-enlargement loss hj=ζ(v1²-v2²)/2g and include it, since omitting it dropped downstream pressure — thus accounting for all loss;
3) Put a flow-straightening run before the expansion, since unsteady turbulence loses heavily — thus calming the flow;
4) Keep the expansion ratio ≤2, since a large ratio raises ζ — thus limiting the ratio;
5) Keep the diffuser wall smooth, since roughness adds loss — thus smoothing the bore;
6) Add downstream pressure compensation, since the pressure drops — thus making it up;
7) Optimize the layout to cut sudden-enlargement points, since each adds loss — thus reducing the count;
8) Write the local loss into the design, since the unchecked loss was the root cause — thus locking it in at design.
GB/T 20801.3-2020 Design code for industrial metallic piping