E44-547 · Heat Exchanger Fouling and Insufficient Heat Transfer · Battery Liquid Cooler - Plate · ★★
Liquid impurities deposit on plates, K drops, cell temperature rises, degradation accelerates
[Mechanism] Liquid impurities deposit on the plates, impeding heat transfer.
[Calculation] Rf=0.3 causes K to drop by 30%, cell temperature to rise by 5℃, and degradation to accelerate.
[Design Omission] No filtration and no cleaning were provided, causing blockage.
1) Install liquid filtration (precision ≤10 μm) with scheduled cleaning (flushing every 2000 h); because liquid impurities deposit on the plates and Rf=0.3 causes K to drop by 30%, cell temperature to rise by 5℃, and degradation to accelerate, filtration restores K and stabilizes cell temperature;
2) Schedule backwashing (reverse flush weekly, force-flush when Δp>0.08 MPa); because fouling buildup causes blockage and K to drop, periodic backwashing restores the flow area;
3) Add a cell-temperature alarm (trigger when cell temperature > design +3℃); because blockage-induced K drop first shows up as cell temperature rise and fast degradation, this gives early warning;
4) Raise flow velocity (≥1.2 m/s) to prevent settling; because liquid impurities settle and deposit in low-velocity zones, higher velocity reduces residence time and suppresses deposition;
5) Use liquid-resistant materials (316L / engineering plastic); because coolant corrodes ordinary materials and corrosion pits promote fouling, liquid-resistant material extends life and suppresses deposition;
6) Add side-stream filtration to reduce impurities (side-stream flow 5–10% of circulation rate); because more impurities mean more deposition and reduced loading suppresses blockage, side-stream filtration cuts impurities;
7) Schedule thickness inspection (measure fouling / fluid quality every two months); because fouling gradually thickens and worsens the K drop and cell temperature rise, quantitative measurement guides cleaning and filtration;
8) Write liquid filtration and scheduled cleaning into the battery-liquid cooling procedure; because the original design omitted filtration and cleaning, the root cause of blockage, the procedure enforces control.
GB/T 151-2014 Heat exchangers