E44-159 · Valve Selection and Internal Leakage · Process Gate Valve · ★★
Long-term throttling erodes the gate; it won't shut tight and internal leakage reaches 8L/min
[Mechanism] Throttling through a gate valve sends a high-velocity stream that erodes the sealing faces.
[Calculation] Damaged faces won't shut tight and leak.
[Design Omission] No throttling valve was used - the gate was misused for throttling, and it leaked.
1) Switch throttling duty to a throttling/control valve, since throttling through the gate eroded the seats and leaked, switching to a dedicated valve;
2) Restrict the gate valve to full-open/full-closed and forbid throttling, since misuse scoured it, limiting its duty;
3) Hardface the sealing faces to resist erosion, since scouring damaged them, hardfacing for erosion resistance;
4) Add a throttling bypass to share the duty, since throttling harms the main valve, splitting it via the bypass;
5) Check internal leakage periodically, since it creeps up, periodic checking;
6) Lap or replace as soon as leakage exceeds the limit, since damaged faces won't seal, repairing the faces;
7) Verify zero internal leakage at shutoff during commissioning, since the design requires measured proof, confirming before handover;
8) Put duty limits into valve selection, since the misuse was the root cause, selection must include them.
GB/T 12234-2019 Steel gate valves