E44-111 · Valve Selection and Internal Leakage · Large-diameter butterfly valve DN1200 · ★★
On the low-pressure side the seating pressure is insufficient; internal leakage 2L/min and shutoff failed
[Mechanism] The low differential pressure drops the sealing-face contact pressure < the required value.
[Calculation] q=Δp·D/(4b)<[q], and the seal fails.
[Design Omission] The low-pressure seating pressure was not checked - leakage followed.
1) Check seating pressure against low differential pressure as q≥[q], since the low-pressure side leaks easily, keeping the seal;
2) Choose a double- or triple-eccentric butterfly valve to raise seating pressure, since the geometry raises it, shutting tight;
3) Add resilient seat compensation, since temperature change deforms it, keeping contact;
4) Set a lower limit on working differential pressure, since below it seating pressure is insufficient, operating in the effective range;
5) Fit online leak detection, since internal leakage is detectable, treating it early;
6) Re-tighten the gland evenly periodically, since loose means leaking, holding pressure;
7) Test leakage ≤0.1L/min at commissioning, since the design requires measured proof, confirming before handover;
8) Put low-pressure seating pressure into butterfly-valve selection, since low pressure was the main cause, locking it in to prevent recurrence.
GB/T 12238-2008 Flanged and wafer-resilient-seated butterfly valves