E44-110 · Valve Selection and Internal Leakage · Soft-Sealed Gate Valve · ★★
The medium is 120℃ (EPDM limit 90℃); the seal aged and cracked, internal leakage 0.3L/min
[Mechanism] Over-temperature degrades the rubber.
[Calculation] Aging rate doubles for every 10℃ over limit; at 120℃ it is 8× faster than at 90℃.
[Design Omission] The material was not selected against medium temperature - cracking and leakage followed.
1) Choose a heat-resistant seal (e.g. FKM or a metal seal) by medium temperature, since over-temperature degrades it, making it heat-resistant;
2) Lower the medium temperature within the material rating, since aging doubles per 10℃ over, extending life;
3) Add spring compensation for seating pressure, since temperature change loosens it, keeping the seal;
4) Replace the seal periodically, since aging is irreversible, maintaining it;
5) Fit online leak detection, since cracking is detectable, treating it early;
6) Use double stem sealing, to prevent external leakage, keeping it safe;
7) Test leakage ≤0.1L/min at commissioning, since the design requires measured proof, confirming before handover;
8) Put temperature-based selection into the valve spec, since the temperature mismatch was the main cause, locking it in to prevent recurrence.
GB/T 12232-2005 General purpose valves - Flanged iron gate valves