E44-483 · Filter Clogging and Contamination · High-Viscosity-Media Filter 100μm · ★★
The medium was highly viscous, heating was insufficient, flow was poor, Δp=0.2MPa, and the filter plugged near its pour point
[Mechanism] Low temperature raised the viscosity η, increasing flow resistance.
[Calculation] η rises exponentially as temperature drops; at 40°C, η=2000cP gives Δp=ξηv/d²=0.2, exceeding the limit.
[Design Omission] No heat tracing to maintain viscosity and no temperature control, so the medium congealed and plugged.
1) Heat-trace the housing and hold temperature >50°C to maintain viscosity; since η=2000cP and Δp=0.2, heat tracing lowers η and restores flow;
2) Heat at the inlet to prevent viscosity buildup; since cooling causes plugging, heating keeps it flowing;
3) Add insulation to prevent heat loss; since heat loss causes congealing, insulation retains heat;
4) Add a viscosity alarm; since high viscosity means high resistance, the alarm warns;
5) Change the screen to a wide-channel design to prevent viscous binding; since narrow passages bind, the wide channel avoids it;
6) Circulate at low flow to prevent stagnation and congealing; since a stopped pump congeals, circulation keeps it moving;
7) Inspect temperature points regularly; since a misreading point biases control, checking them ensures accuracy;
8) Write heat tracing and temperature control into the viscous-media procedure; since the medium was never heated, the root cause of congealing, the procedure provides the check.
GB/T 26114-2010 Filters for liquid filtration